| Product number | JUT3-4 | JUT3-4PE |
| product type | Rail Terminals | Rail ground terminal |
| Mechanical structure | pull back spring | pull back spring |
| layers | 1 | 1 |
| Electric potential | 1 | 1 |
| connection volume | 2 | 2 |
| Rated cross section | 4 mm2 | 4mm2 |
| Rated current | 32A | |
| Rated voltage | 800V | |
| open side panel | Yes | Yes |
| grounding feet | no | Yes |
| other | The total current of all connecting wires must not exceed the maximum load current. | Please pay attention to the ampacity of the rail. |
| Application field | Railway industry, mechanical engineering, plant engineering, process engineering | Railway industry, mechanical engineering, plant engineering, process engineering |
| color | gray、customizable | yellow and green |
| line contact | ||
| Stripping length | 8mm | 8mm |
| Rigid Conductor Cross Section | 0.08mm² — 6mm² | 0.08mm² — 6mm² |
| Flexible conductor cross section | 0.08mm² — 4mm² | 0.08mm² — 4mm² |
| Rigid Conductor Cross Section AWG | 28-10 | 28-10 |
| Flexible Conductor Cross Section AWG | 28-12 | 28-12 |
| thickness | 6.2mm | 6.2mm |
| width | 56mm | 56mm |
| high | ||
| NS35/7.5 high | 36.5mm | 36.5mm |
| NS35/15 high | 44mm | 44mm |
| NS15/5.5 high |
| Flame retardant grade, in line with UL94 | V0 | V0 |
| Insulation Materials | PA | PA |
| Insulation material group | I | I |
| standard test | IEC 60947-7-1 | IEC 60947-7-2 |
| Rated voltage(III/3) | 800V | |
| Rated current(III/3) | 32A | |
| Rated surge voltage | 8kv | 8kv |
| Overvoltage class | III | III |
| pollution level | 3 | 3 |
| Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
| Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
| Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C |
| Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C |
| Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % |
| RoHS | No excessive harmful substances | No excessive harmful substances |
| Connections are standard | IEC 60947-7-1 | IEC 60947-7-2 |
| Surge Voltage Test Results | Passed the test | Passed the test |
| Power frequency withstand voltage test results | Passed the test | Passed the test |
| Temperature rise test results | Passed the test | Passed the test |